Calculating Temperature from Fireline Intensity
Authored By: D. Kennard
Expected temperatures at any height above a surface fire can be estimated or calculated from ambient temperature and fireline intensity (Van Wagner 1973,1975):
BT = 3.9 (I)2/3 / hwhere:
- T = temperature rise above ambient (C)
- I = fireline intensity (kW/m)
- h = height above ground (m)
Click to view citations...
Literature Cited